nanaxland.blogg.se

Split Phase Motor Pdf
split phase motor pdf









Speed-Torque Characteristics of Single-Phase, Single Main Winding Only Motor Two basic mathematical models best reveal two important facts about single-phase motors: 1. Our products are usedWhat is major difference between a 3-phase induction motor and a single-phase induction motor?Figure 8. Starting the motor can be achieved by designing the stator with two windings, a main and auxiliary coil.Single phase motors 63 - 100L 2227E Issue 1e Single phase motors Brook Crompton Brook Crompton is a leading manufacturer of electric motors for the global industrial market, with motor solutions which benefit a wide range of customers. This leads to the three main types of single-phase induction motor: shaded-pole , split-phased, and capacitor motors. A single-phase motor with a coil winding is the simplest type of AC motor but needs a starting mechanism.

split phase motor pdf

Note that the resultant vector of two revolving flux vectors is a stationary vector that oscillates in length with time along X-axis.What is the position of rotor at standstill?Consider the case that the rotor is stationary and the stator winding is connected to a single-phase supply. This theory is based on the fact that an alternating sinusoidal flux can be represented by two revolving fluxes, each equal to one-half of the maximum value of alternating flux (i.e., m/2) and each rotating at synchronous speed in opposite directions.Therefore, an alternating field can be replaced by two relating fields of half its amplitude rotating in opposite directions at synchronous speed. Nor can it be employed fur a motor located at some inaccessible spot.Explain why single phase induction motor does not start in the light of Double-Field Revolving Theory?The double-field revolving theory is proposed to explain this dilemma of no torque at start and yet torque once rotated. This method of starting is generally not convenient for large motors. Once the motor is running at this speed, it will continue to rotate even though single-phase current is flowing through the stator winding.

However, when the rotor rotates, the impedances of the two rotor circuits are unequal and the rotor current I2b is higher (and also at a lower power factor) than the rotor current I2f. Therefore, rotor currents are equal i.e., I2f = I2b. The value of 100% slip (standstill condition) is the same for both the fields.Explain motor action from standstill to running condition?At standstill, s = 1 so that impedances of the two circuits are equal. Thus the point of zero slip for one field corresponds to 200% slip for the other. Therefore, single-phase induction motor is not self-starting.Note that each rotating field tends to drive the rotor in the direction in which the field rotates.

Once so started, the motor will continue to run on single-phase supply.What is the major cause of noisy operation of the single phase induction motor?If the two windings arc displaced 90° electrical but produce fields that are not equal and that are not 90° apart in time, the resultant field is still rotating but is not constant in magnitude. With the exception of the shaded-pole motor, all single-phase induction motors are started as 2-phase machine. When the motor attains sufficient speed, the starting means (i.e., additional winding) may be removed depending upon the type of the motor.Name the types of single phase motors with respect to the method employed to make them self-starting?(i) Split-phase motors-started by two phase motor action through the use of an auxiliary or starting winding.(ii) Capacitor motors-started by two-phase motor action through the use of an auxiliary winding and a capacitor.(iii) Shaded-pole motors-started by the motion of the magnetic field produced by means of a shading coil around a portion of the pole structure.How to produce Rotating Magnetic Field From 2-Phase Supply?As with a 3-phase supply, a 2-phase balanced supply also produces a rotating magnetic field of constant magnitude. To make a single-phase induction motor self-starting, we should somehow produce a revolving stator magnetic field.This may be achieved by converting a single-phase supply into two-phase supply through the use of an additional winding. The motor-quickly accelerates to the final speed.How to make Single-Phase Induction Motor Self-Starting?The single-phase induction motor is not self- starting and it is undesirable to resort to mechanical spinning of the shaft or pulling a belt to start it.

Consequently, a weak revolving field approximating to that of a 2-phase machine is produced which starts the motor. Since main winding is made highly inductive while the starting winding highly resistive, the currents Im and Is have a reasonable phase angle a (25° to 30°) between them as shown in Fig. Consequently, the currents flowing in the two windings have reasonable phase difference c (25° to 30°) as shown in the phasor diagram in Fig.When the two stator windings are energized from a single-phase supply, the main winding carries current Im while the starting winding carries current Is. The two windings are so resigned that the starting winding S has a high resistance and relatively small reactance while the main winding M has relatively low resistance and large reactance as shown in the schematic connections in Fig. The starting winding is located 90° electrical from the main winding and operates only during the brief period when the motor starts up. Since 2-phase operation ceases once the motor is started, the operation of the motor then becomes smooth.Describe the principal of operation of Split-Phase Induction Motor?The stator of a split-phase induction motor is provided with an auxiliary or starting winding S in addition to the main or running winding M.

If the starting period exceeds 5 seconds, the winding may burn out unless the motor is protected by built-in-thermal relay. The normal speed of the motor is below the synchronous speed and depends upon the load on the motorWhat is starting torque and starting current of split phase induction motor?The spinning torque is 15 to 2 times the full-loud torque mid (lie starting current is 6 to 8 times the full-load current.Why split-phase induction motors are most popular single- phase motors in the market?Due to their low cost, split-phase induction motors are most popular single- phase motors in the marketWhy built-in-thermal relay is necessary in split phase induction motor and what is its purpose?Since the starting winding is made of fine wire, the current density is high and the winding heats up quickly. The motor then operates as a single-phase induction motor and continues to accelerate till it reaches the normal speed.

split phase motor pdf